Buy Freon Hot Shot™ 2 R-417C Wholesale HFC Refrigerant Gas | R-12 Replacement

Buy Freon Hot Shot™ 2 R-417C Wholesale HFC Refrigerant Gas | R-12 Replacement for suitable commercial, industrial, refrigeration and air-conditioning applications. Freon Hot Shot™ 2 is an HFC replacement refrigerant designed primarily for systems using R-12 and selected R-12 replacement blends. It can also be used in suitable R-134a and R-500 systems according to Chemours technical guidance.

Freon Hot Shot™ 2 is classified ASHRAE A1, is nonflammable, has zero ozone depletion potential (ODP), and is compatible with commonly used compressor lubricants including mineral oil (MO), alkylbenzene (AB), and polyolester (POE).

Buy Freon Hot Shot™ 2 R-417C Wholesale HFC Refrigerant Gas | R-12 Replacement Overview

Freon Hot Shot™ 2 (R-417C) is formulated as a replacement refrigerant for legacy CFC and HCFC replacement applications where a suitable HFC alternative is required.

According to the official Freon™ product information, R-417C can retrofit systems currently operating with R-12 or R-12 blends, including R-401A, R-401B, R-409A, R-414A, R-414B, R-416A, R-420A, R-426A, R-437 and R-500. Chemours technical documentation also identifies suitable R-12, R-134a and R-500 applications.

The refrigerant is designed for systems using direct-expansion metering devices, including TXVs, orifices and capillary tubes. Chemours states that in suitable retrofit applications, a TEV or capillary-tube replacement is not required.

Buy Freon Hot Shot™ 2 R-417C Wholesale HFC Refrigerant Gas | R-12 Replacement Technical Specifications

Specification Freon Hot Shot™ 2 (R-417C)
Brand Freon™
Product Name Freon Hot Shot™ 2
ASHRAE Designation R-417C
Refrigerant Type HFC Blend
Composition R-125 / R-134a / R-600
Composition by Weight 19.5% / 78.8% / 1.7%
Molecular Weight 103.73 g/mol
Boiling Point at 1 atm -32.59°C (-26.65°F)
Critical Temperature 95.4°C (203.7°F)
Critical Pressure 4073.767 kPa abs
Liquid Density at 21.1°C 1194.98 kg/m³
Safety Classification A1
Flammability Nonflammable
Ozone Depletion Potential 0
AR5 GWP 1,643
Temperature Glide Approximately 3 K
Lubricant Compatibility MO, AB and POE
Primary Replacement R-12
Other Suitable Applications R-134a and R-500 systems, subject to application
Application Type Low, medium and high temperature refrigeration; selected AC
Supply Refrigerant Gas / Cylinder
Commercial Supply Wholesale / Bulk

Technical values are from Chemours’ published Hot Shot-2 product information.

Main Applications of Freon Hot Shot™ 2

Low-Temperature Refrigeration

R-417C can be used in suitable low-temperature refrigeration applications where an appropriate replacement for R-12 or other listed legacy refrigerants is required.

Potential equipment includes:

  • Commercial refrigeration
  • Refrigerated storage
  • Low-temperature refrigeration
  • Food refrigeration
  • Refrigeration service equipment
  • Direct-expansion refrigeration systems

Medium-Temperature Refrigeration

Freon Hot Shot™ 2 is also suitable for selected medium-temperature refrigeration applications.

System performance should be evaluated according to the evaporating temperature, condensing temperature, compressor, metering device, refrigerant charge and system load.

High-Temperature Refrigeration

Chemours technical documentation identifies R-417C for suitable R-12 and R-134a low-, medium- and high-temperature refrigeration applications.

Air Conditioning

Freon Hot Shot™ 2 is identified for suitable R-12 and R-500 air-conditioning applications.

R-12 Replacement Refrigerant

One of the principal uses of Freon Hot Shot™ 2 is replacing R-12 in suitable systems.

R-12 is a CFC refrigerant subject to phase-out and restrictions in many markets. R-417C provides an HFC-based alternative for suitable existing equipment.

Freon™ specifically identifies Hot Shot™ 2 as an R-12 replacement and lists a range of R-12 replacement blends for which it can be used in suitable retrofit applications.

R-12 and R-500 Replacement Applications

R-417C can be considered for suitable systems originally designed for:

  • R-12
  • R-500
  • R-401A
  • R-401B
  • R-409A
  • R-414A
  • R-414B
  • R-416A
  • R-420A
  • R-426A
  • R-437

System-specific compatibility must be confirmed before conversion.

R-134a Applications

Chemours’ Hot Shot-2 conversion documentation identifies R-417C for suitable R-134a systems, including low-, medium- and high-temperature refrigeration applications.

This should not be interpreted as universal drop-in compatibility. The actual equipment design, compressor, lubricant, metering device, operating conditions and manufacturer instructions must be evaluated before conversion.

Lubricant Compatibility

A major advantage of Freon Hot Shot™ 2 is its compatibility with several compressor oil types.

Mineral Oil — MO

R-417C is compatible with mineral oil in suitable applications.

Alkylbenzene — AB

Alkylbenzene lubricants are also compatible with Hot Shot™ 2.

Polyolester — POE

POE lubricants are compatible with suitable R-417C systems.

Chemours states that Hot Shot™ 2 is compatible with traditional and new lubricants and that in most cases no lubricant change is required. However, oil condition and equipment requirements must still be evaluated during a retrofit.

Direct-Expansion System Compatibility

Freon Hot Shot™ 2 is designed for systems using direct-expansion metering devices such as:

  • TXV / TEV
  • Orifice
  • Capillary tube

Chemours’ conversion guidance states that a TEV or capillary tube replacement is not required for the recommended retrofit procedure.

Benefits of Freon Hot Shot™ 2

Zero Ozone Depletion Potential

R-417C has an ODP of zero, making it a non-ozone-depleting HFC alternative to R-12.

A1 Safety Classification

R-417C is classified ASHRAE A1, indicating a nonflammable refrigerant classification under the applicable standard.

Broad Lubricant Compatibility

Compatibility with MO, AB and POE lubricants can simplify suitable retrofit projects.

Existing Equipment Retrofit

R-417C is intended for suitable existing systems, allowing refrigeration equipment to be evaluated for conversion rather than automatically requiring complete replacement.

Widespread Availability

Freon™ identifies widespread availability as one of Hot Shot™ 2’s product benefits.

GWP and Environmental Considerations

Chemours lists an AR5 GWP of 1,643 for R-417C.

Although R-417C has zero ozone depletion potential, its GWP remains relevant to current refrigerant regulations. Refrigerant rules vary by country, region and application and can change over time.

Where a lower-GWP solution is required, Chemours directs users toward its Opteon™ refrigerant portfolio.

R-417C Retrofit Procedure

A professional retrofit should be carried out according to the equipment manufacturer’s requirements and applicable refrigerant regulations.

Chemours’ published conversion guidance includes the following general process:

1. Record Existing System Data

Record operating conditions before removing the original refrigerant.

Important measurements can include:

  • Suction pressure
  • Discharge pressure
  • Superheat
  • Subcooling
  • Temperature readings
  • Refrigerant charge
  • Compressor operating conditions

2. Recover the Existing Refrigerant

Recover the original refrigerant using approved recovery equipment and procedures.

3. Check the Oil

Chemours recommends evaluating the system oil for acidity, water and solids. If contamination is identified, the oil should be serviced according to OEM requirements.

4. Replace Filtration Components

Install an appropriate filter drier and service oil filters where required.

5. Leak Check

Pressure-test the system with dry nitrogen without exceeding the equipment’s design pressure.

6. Evacuate

Evacuate the system to remove moisture and non-condensable gases. Chemours’ published procedure specifies a minimum 500-micron vacuum.

7. Charge With R-417C

Chemours’ conversion guide instructs technicians to charge Hot Shot-2 as liquid and provides application-specific charging guidance. Follow the manufacturer’s current instructions rather than using a generic charge amount.

8. Test System Performance

After charging, check:

  • Suction pressure
  • Discharge pressure
  • Superheat
  • Subcooling
  • System temperatures
  • Compressor operation
  • Refrigeration capacity

9. Label the System

Clearly identify the new refrigerant to prevent accidental mixing with other refrigerants.

Important Retrofit Considerations

Conversion from CFC or HCFC refrigerants to HFC refrigerants can affect certain elastomers and O-rings. Chemours advises checking these components during conversion because they can retract after the refrigerant change.

Before purchasing R-417C for a retrofit, confirm:

  • Existing refrigerant
  • Compressor model
  • Compressor oil
  • System operating temperature
  • Metering device
  • System capacity
  • Refrigerant charge
  • Equipment condition
  • Leak condition
  • OEM recommendations
  • Local refrigerant regulations

Wholesale Freon Refrigerant Gases

We supply Freon Refrigerant Gases for wholesale and bulk refrigeration requirements, subject to availability and applicable regulations.

Wholesale customers can request:

  • Bulk R-417C pricing
  • Cylinder sizes
  • Commercial quantities
  • Industrial quantities
  • Export supply
  • Shipping arrangements
  • Repeat orders
  • Distributor supply
  • Project quantities

Request a Wholesale Quote

Buy Genuine Freon Refrigerant Gas

For commercial and industrial applications, verify that the refrigerant is genuine Freon™ Hot Shot™ 2 and correctly identified as R-417C.

Before accepting a shipment, check:

  • Product name
  • R-417C designation
  • Cylinder labeling
  • Packaging condition
  • Safety documentation
  • Supplier information
  • Product documentation
  • Applicable authenticity features

Purchasing from an established refrigerant supplier helps reduce the risk associated with unidentified or incorrectly labeled refrigerant.

Safety and Handling

Freon Hot Shot™ 2 is nonflammable and A1 classified, but it remains a pressurized refrigerant and must be handled by appropriately trained personnel.

Always:

  • Review the current SDS before use.
  • Use suitable PPE.
  • Work in adequately ventilated areas.
  • Use equipment rated for the refrigerant.
  • Recover refrigerant with approved equipment.
  • Avoid intentional refrigerant release.
  • Keep cylinders away from excessive heat.
  • Follow transportation requirements.
  • Follow applicable local refrigerant regulations.

Frequently Asked Questions

What is Freon Hot Shot™ 2?

Freon Hot Shot™ 2 is the Freon™ brand designation for R-417C, an HFC refrigerant replacement used in suitable R-12 and selected legacy refrigerant systems.

Is R-417C an HFC refrigerant?

Yes. R-417C is an HFC refrigerant blend consisting of R-125, R-134a and R-600.

Can I buy wholesale?

Yes. Wholesale and bulk purchase requirements can be quoted according to quantity, packaging, destination and applicable regulations.

Related Freon Refrigerants

For customers comparing refrigerant replacement products, related Freon™ products include:

  • Freon One Shot™ C R-422C
  • Freon™ MO49Plus R-437A
  • Freon™ MO59 R-417A
  • Freon™ MO79 R-422A
  • Freon™ NU-22B™ R-422B
  • Freon™ 134a R-134a
  • Freon™ 507 R-507A

Reviews

There are no reviews yet.

Be the first to review “Buy Freon Hot Shot™ 2 R-417C Wholesale HFC Refrigerant Gas | R-12 Replacement”

Your email address will not be published. Required fields are marked

Buy Freon Hot Shot™ 2 R-417C Wholesale Buy Freon Hot Shot™ 2 R-417C W...

$95.00