$130.00
Buy Freon One Shot™ C R-422C Wholesale HFC Refrigerant Gas | R-22 Replacement for suitable R-22, R-404A, R-507A and low-temperature refrigeration applications. Request pricing.
Buy Freon One Shot™ C R-422C Wholesale HFC Refrigerant Gas | R-22 Replacement for suitable low- and medium-temperature commercial and industrial refrigeration systems. Freon One Shot™ C is an HFC refrigerant blend developed for retrofit and replacement applications involving R-22 and other selected legacy refrigerants, including R-402A, R-402B, R-404A, R-408A, R-502, and R-507A.
Freon One Shot™ C is classified ASHRAE A1, is nonflammable, and has zero ozone depletion potential. It is compatible with several commonly used refrigeration lubricants, including mineral oil, alkylbenzene and POE, subject to equipment-specific requirements.
Freon One Shot™ C is designed for refrigeration service and retrofit applications where an appropriate alternative to an existing refrigerant is required.
The refrigerant is particularly relevant to commercial and industrial refrigeration equipment operating at low and medium temperatures. Its application range includes refrigeration systems used for food storage, food-service equipment, supermarket refrigeration and other compatible commercial refrigeration installations.
R-422C can be considered for suitable systems originally designed around refrigerants such as R-22, R-404A, R-507A, R-502 and other refrigerants identified by the manufacturer.
A refrigerant conversion should always be evaluated according to the specific compressor, system design, operating conditions, lubricant, expansion device and manufacturer’s recommendations.
| Specification | Freon One Shot™ C (R-422C) |
|---|---|
| Brand | Freon™ |
| Product | Freon One Shot C |
| ASHRAE Designation | R-422C |
| Refrigerant Type | HFC Blend |
| Refrigerant Category | HFC Refrigerant |
| Safety Classification | A1 |
| Flammability | Nonflammable |
| Ozone Depletion Potential | 0 |
| Primary Applications | Low- and medium-temperature refrigeration |
| Main Retrofit Applications | R-22 and selected legacy refrigerants |
| Lubricant Compatibility | Mineral Oil, Alkylbenzene, POE |
| Refrigerant Form | Liquefied refrigerant gas |
| Supply | Cylinders / commercial packaging |
| Commercial Availability | Wholesale and bulk supply subject to availability |
Freon One Shot™ C can be used in suitable commercial refrigeration systems, including applications such as:
R-422C may also be suitable for selected industrial refrigeration equipment where its operating characteristics meet the system requirements.
Applications should be evaluated based on:
One of the major applications for Freon One Shot™ C is the replacement of R-22 in suitable refrigeration systems.
For an R-22 retrofit, the technician should evaluate the existing system before charging R-422C. Refrigerant replacement is not automatically suitable for every R-22 installation.
Important considerations include:
Proper recovery of the existing refrigerant should be completed before conversion where required.
Freon™ identifies R-422C for suitable systems using several refrigerants, including:
The suitability of R-422C depends on the equipment and application. A replacement designation should not be interpreted as universal compatibility across every system.
Freon One Shot™ C offers compatibility with commonly encountered refrigeration oils.
Compatible lubricant categories identified for suitable applications include:
R-422C can be used with mineral-oil systems where the equipment and retrofit procedure permit.
Alkylbenzene lubricants are also compatible with suitable R-422C applications.
POE lubricants may also be used in appropriate equipment.
The exact lubricant requirement should always be confirmed with the compressor or equipment manufacturer before conversion.
Freon One Shot™ C is intended to provide useful refrigeration performance while allowing suitable existing equipment to remain in service.
Key characteristics include:
Freon™ also identifies R-422C as providing higher capacity than R-507A in suitable applications.
R-404A has historically been widely used in commercial and industrial low-temperature refrigeration.
Freon One Shot™ C is identified for suitable R-404A systems. When considering a conversion, system capacity, operating temperatures, pressure characteristics and regulatory requirements should be evaluated before making the change.
R-422C is therefore relevant to refrigeration service companies managing equipment originally designed around older refrigerant platforms.
R-422C is also identified for suitable R-507A applications.
Freon™ states that R-422C provides higher capacity than R-507A in applicable systems. Actual system performance depends on the equipment configuration and operating conditions.
Freon One Shot™ C has zero ozone depletion potential (ODP).
Freon™ also states that R-422C has approximately 20% lower GWP than R-404A and R-507A.
However, R-422C should not automatically be considered a low-GWP refrigerant. Environmental regulations and refrigerant requirements vary between countries and applications and can change over time.
For installations requiring substantially lower-GWP refrigerants, alternative refrigerant technologies should be evaluated based on the application and applicable regulations.
Freon One Shot™ C is classified ASHRAE A1.
A1 indicates the refrigerant falls within the lowest toxicity and no-flame-propagation classification under the applicable ASHRAE refrigerant safety classification system.
Even though R-422C is nonflammable, it remains a pressurized refrigerant and must be handled correctly.
Freon One Shot™ C can be considered when you need:
We offer Freon One Shot™ C R-422C for wholesale and bulk refrigeration requirements, subject to stock, packaging and applicable regulations.
Wholesale customers can request:
Original Refrigerant: R-22 / R-404A / R-507A / Other
For professional refrigeration applications, purchasing genuine refrigerant from an established and reputable supply channel is important.
Before accepting a shipment, check:
Using unidentified, incorrectly labeled or counterfeit refrigerant can create equipment-performance and safety concerns.
R-422C should be handled by trained refrigeration professionals using equipment appropriate for pressurized refrigerants.
Always:
Before converting a system to R-422C, verify:
Identify the refrigerant currently installed and recover it according to applicable requirements.
Confirm compressor compatibility and operating requirements.
Verify whether the existing mineral oil, alkylbenzene or POE lubricant is appropriate.
Evaluate the expansion valve or other metering device for the new refrigerant.
Check evaporating and condensing temperatures.
Confirm that the expected capacity meets the refrigeration load.
Follow the correct charging procedure for the refrigerant and equipment.
Inspect and test the system for leaks before returning it to service.
Monitor suction pressure, discharge pressure, superheat, subcooling and system temperatures as appropriate.
Always follow the equipment manufacturer’s instructions where available.
Freon One Shot™ C is an HFC refrigerant blend designated R-422C, intended for suitable low- and medium-temperature refrigeration applications.
Yes. Freon One Shot™ C R-422C is an HFC refrigerant blend.
R-422C is identified for suitable R-22 replacement applications. System compatibility and retrofit requirements must be verified before conversion.
Freon™ identifies R-422C for suitable systems using R-404A. Equipment-specific evaluation is required.
Yes, R-422C is identified for suitable R-507A applications. Freon™ states that it provides higher capacity than R-507A under applicable conditions.
No. R-422C is classified ASHRAE A1 and is identified as nonflammable.
Yes. Freon™ identifies R-422C as having zero ozone depletion potential.
Freon™ identifies mineral oil, alkylbenzene and POE as compatible lubricant types for suitable applications.
Yes. Low-temperature refrigeration is one of the primary application areas for Freon One Shot™ C.
Yes. R-422C is also intended for suitable medium-temperature refrigeration systems.
Yes. Wholesale and bulk supply can be requested, subject to availability, destination and applicable refrigerant regulations.
Customers comparing Freon™ refrigeration products may also consider:
For the latest product specifications, technical documentation, safety information and application guidance, consult the official Freon™ product documentation and the relevant equipment manufacturer.
Freon One Shot™ C (R-422C) is a wholesale HFC refrigerant gas for suitable low- and medium-temperature commercial and industrial refrigeration applications. It is identified for replacement applications involving R-22, R-402A, R-402B, R-404A, R-408A, R-502 and R-507A. With an A1 classification, nonflammability, zero ODP and compatibility with mineral oil, alkylbenzene and POE lubricants, R-422C is relevant to a wide range of refrigeration retrofit and service requirements.
For commercial quantities, request a wholesale quotation for Freon One Shot™ C R-422C, including cylinder size, quantity, destination and shipping requirements.
Reviews
There are no reviews yet.